Skip to content

MVisionPro Engineering Tools

by mvisionpro.com · remote · no sign-in to list tools · v1.0.0 · published by com.mvisionpro

Read-only machine-vision calculations for optics, interfaces, line scan, sensors, and models.

Changes · 3

6 tools: 3 change things and 3 only read.

Scanned Oct 21, 2026

No check matched anything in the tool definitions. No finding is not a safety guarantee. How the checks work.

claude mcp add --transport http tools https://mvisionpro.com/tools/mcp

Tools

Open a tool for its reasons and full description. Descriptions are the publisher's own words, shown as they are.

6 tools

Changes things 3Claude Code: ask
  • interfaceCalculate stream bandwidth and evaluate interface options.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Calculate stream bandwidth and evaluate interface options. Provide either camera or the complete manual stream set widthPx, heightPx, fps, bits, streamType and packed; do not combine the two modes. width and height are independent aliases for widthPx and heightPx, so mixed alias pairs are accepted, but do not send both aliases for one axis. The discovery alternatives describe complete sets; execution also rejects partial manual sets and every camera/manual mixture, for example camera with widthPx.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false
  • linescanCalculate line width, line rate, exposure and confirmed camera modes.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Calculate line width, line rate, exposure and confirmed camera modes. widthMm is required. Provide exactly one speed field (speedMmS or speedMMin) and exactly one calculation set (defectMm+nPx or accuracyMm+kPx); mode is inferred when omitted. samplingMode defaults to xy, or to width when longitudinalStepMm is present.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false
  • opticsCalculate camera geometry, object sampling, exposure and depth of field.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Calculate camera geometry, object sampling, exposure and depth of field. Provide exactly one sensor source: camera, sensor, or both manual sensor axes. Camera cannot be combined with manual passport fields. fovMm and wdMm are always required.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false
Only reads 3Claude Code: allow
  • analogCompare one unambiguous competitor model with bounded Hikrobot candidates.No findings

    Why it is in this group

    • The description's first verb is "compare": a word for reading.
    Description, as the server wrote it
    Compare one unambiguous competitor model with bounded Hikrobot candidates. Compare one unambiguous competitor model with a bounded set of public Hikrobot candidates.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false
  • modelsSearch the bounded public catalog projection.No findings

    Why it is in this group

    • The description's first verb is "search": a word for reading.
    Description, as the server wrote it
    Search the bounded public catalog projection. Search the bounded public catalog projection by literal model, alias, SKU or slug.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false
  • sensorsGet a sensor aggregation by exactly one camera model or sensor part.No findings

    Why it is in this group

    • The description's first verb is "get": a word for reading.
    Description, as the server wrote it
    Get a sensor aggregation by exactly one camera model or sensor part. Provide exactly one lookup key: a catalog camera model or a sensor part number.

    Annotations the server declares

    • readOnlyHint: true
    • idempotentHint: true
    • openWorldHint: false

This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.

Install

Pinned to version 1.0.0. Values in angle brackets are yours to fill in.

claude mcp add --transport http tools https://mvisionpro.com/tools/mcp

Run in a terminal.

Claude Code permissions

Allow the reads, ask before a change, deny the deletes. Paste into .claude/settings.json.

.claude/settings.json
{
  "permissions": {
    "allow": [
      "mcp__tools__analog",
      "mcp__tools__sensors",
      "mcp__tools__models"
    ],
    "ask": [
      "mcp__tools__optics",
      "mcp__tools__interface",
      "mcp__tools__linescan"
    ],
    "deny": []
  }
}

Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. It assumes the server is installed as tools. Review it before you use it.