NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

Deletes · 1Changes · 9

10 tools: 1 can delete or cancel things and 9 change things.

Scanned Oct 21, 2026

5 checks matched something in the tool definitions. No finding is not a safety guarantee. How the checks work.

claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp

Findings

Matches of fixed checks, with the text they matched.

5 warn
  • The server marks "voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

    What this check looks for
  • The server marks "voltage_drop" not destructive (destructiveHint: false), and its own name, description or input give the class "destructive".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

    What this check looks for
  • The server marks "conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "conduit_fill" says "fill": a word for a change.

    What this check looks for
  • The server marks "box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "box_fill" says "fill": a word for a change.

    What this check looks for
  • The server marks "panel_schedule" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "panel_schedule" says "schedule": a word for a change.

    What this check looks for

Tools

Open a tool for its reasons and full description. Descriptions are the publisher's own words, shown as they are.

10 tools

Deletes or cancels 1Claude Code: deny
  • voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).2 findings

    Why it is in this group

    • The name "voltage_drop" says "drop": a word for removing or ending something.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    • The server marks it not destructive (destructiveHint: false), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

      What this check looks for
    • Warn

      The server marks "voltage_drop" not destructive (destructiveHint: false), and its own name, description or input give the class "destructive".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

      What this check looks for
    Description, as the server wrote it
    Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

    Annotations the server declares

    • title: Voltage drop calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
Changes things 9Claude Code: ask
  • bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

    Annotations the server declares

    • title: Electrical bid calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.1 finding

    Why it is in this group

    • The name "box_fill" says "fill": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "box_fill" says "fill": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

    Annotations the server declares

    • title: Box fill calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.1 finding

    Why it is in this group

    • The name "conduit_fill" says "fill": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "conduit_fill" says "fill": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

    Annotations the server declares

    • title: Conduit fill calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minim…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.

    Annotations the server declares

    • title: Residential load calculator (NEC 220.82)
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or …No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.

    Annotations the server declares

    • title: NEC Table 310.16 ampacity lookup
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

    Annotations the server declares

    • title: Ohm's law calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.1 finding

    Why it is in this group

    • The name "panel_schedule" says "schedule": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "panel_schedule" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "panel_schedule" says "schedule": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

    Annotations the server declares

    • title: Panel schedule generator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

    Annotations the server declares

    • title: Watts to amps calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

    Annotations the server declares

    • title: Wire size calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false

This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.

Install

Pinned to version 1.0.1. Values in angle brackets are yours to fill in.

claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp

Run in a terminal.

Claude Code permissions

Allow the reads, ask before a change, deny the deletes. Paste into .claude/settings.json.

.claude/settings.json
{
  "permissions": {
    "allow": [],
    "ask": [
      "mcp__nec-calculators__wire_size",
      "mcp__nec-calculators__watts_to_amps",
      "mcp__nec-calculators__conduit_fill",
      "mcp__nec-calculators__box_fill",
      "mcp__nec-calculators__load_calculator",
      "mcp__nec-calculators__ohms_law",
      "mcp__nec-calculators__panel_schedule",
      "mcp__nec-calculators__bid_calculator",
      "mcp__nec-calculators__nec_ampacity"
    ],
    "deny": [
      "mcp__nec-calculators__voltage_drop"
    ]
  }
}

Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. It assumes the server is installed as nec-calculators. Review it before you use it.